All of our information is sourced from manufacturer data.

ThermoSeal CCX

ThermoSeal, LLC

ThermoSeal CCX

One-Click Request

Acelab will find & contact reps to deliver answers to your inbox.

Overview

Sprayed Insulation Sprayed Insulation

Polyurethane Polyurethane

Ceiling, Crawl-Space Ceiling, Floor, Sloped Ceiling Ceiling, Crawl-Space Ceiling, Floor, Sloped Ceiling

In between Wood (or Steel) Studs, Unfinished Floor In between Wood (or Steel) Studs, Unfinished Floor

Design Options

Product Description

ThermoSeal CCX is a two component, semi-rigid, medium density, 2 lb closed cell polyurethane foam insulation system which simultaneously insulates and air-seals your building structure. It requires the use of an “A” component (ISO) and a blended "B" component (RESIN), which contains ZERO ozone depleting catalysts, polyols and fire retarding materials.
ThermoSeal CCX is designed to make homes more energy efficient, quieter, healthier and more comfortable. It is applied as a liquid spray which expands approximately 15 times its initial mass and cures within seconds into a semi-rigid mass. It fills all building cavities completely sealing all cracks, crevices, and voids where air loss and infiltration are most common.

Insulation

Width

Height

Thickness

Standard Sizes: 1", 2", 3", 3-1/2", 4", 5", 5-1/2", 6", 7", 7-3/4", 8", 9", 10", 11", 12", 13", 14", 15", 16"

Performance Data

R-Value Per Inch

Measure of the thermal resistance of the product per inch of thickness, imperial units.

°F·ft^2·h / BTU / inch

6.7

NRC Value

The Noise Reduction Coefficient values of this product

Fire Resistance

Amount of time the product can withstand fire

Water Vapor Transmission

An imperial perm is defined as 1 grain of water vapor per hour, per square foot, per inch of mercury

perm (imperial)

1

Compressive Strength

psi

18

Dimensional Stability

The percent that a product's dimensions vary due to aging or environmental conditions.

%

4.14

Smoke Development

As defined by the ASTM E84 testing standard

350

Flame Spread

As defined by the ASTM E84 testing standard

5

Product Density

lbs / ft^3

2.17

R-Value

Measure of the thermal resistance of the product, imperial units.

°F·ft^2·h / BTU

6.7, 13, 19, 23, 26, 32, 35, 39, 45, 50, 51, 58, 64, 71, 77, 84, 90, 97, 103

Tensile Strength

psf

2592