All of our information is sourced from manufacturer data.

 PW 100/40 Air/Vapor Barrier

Protecto Wrap Co.

PW 100/40 Air/Vapor Barrier

One-Click Request

Acelab will find & contact reps to deliver answers to your inbox.

Overview

Vapor Retarder (Class I) Vapor Retarder (Class I)

Fully Adhering Fully Adhering

Bitumen Bitumen

Ceiling, Sloped Roof, Wall Ceiling, Sloped Roof, Wall

Concrete, Masonry Concrete, Masonry

Design Options

Product Description

A peel and stick membrane for use as a positive air/vapor stop in everyday construction.

Sheet Width

Width

Standard Sizes: 4", 6", 9", 1' 0", 1' 6", 2' 0", 3' 0"

Height

Thickness

Sheet Length

Width

Height

Standard Sizes: 6' 3"

Thickness

Thickness

Width

Height

Thickness

Standard Sizes: 0"

Manufacturer Design Notes

As a full building wrap in envelope applications in cavity wall construction.

Performance Data

Air Permeance

Rate of airflow through the barrier per square foot at a specified pressure difference

Product Weight Per Area

Roll Tensile Strength

Weight needed to break the roll, per inch of width

Water Vapor Transmission

An imperial perm is defined as 1 grain of water vapor per hour, per square foot, per inch of mercury

perm (imperial)

0.01

Minimum Temperature Rating

The lowest temperature that the product has been confirmed to still function at.

°F

-45

Minimum Application Temperature

Minimum temperature that the product can be applied or installed

°F

40

Film Tensile Strength

Pressure required to break the film

psi

975

Protecto Wrap Co.

1955 South Cherokee Street Denver 80223

1 (800) 759-9727