Tremco
ExoAir 110AT
One-Click Request
Overview
Vapor Retarder (Class I)
Fully Adhering
Butyl
Ceiling, Sloped Roof, Wall
Concrete, Masonry
Design Options
Product Description
Sheet Width
Width
Standard Sizes: 4", 9", 1' 6", 3' 0"
Height
Thickness
Sheet Length
Width
Height
Standard Sizes: 6' 3"
Thickness
Thickness
Width
Height
Thickness
Standard Sizes: 0"
Manufacturer Design Notes
Typically applied to exterior sheathing boards and concrete block, ExoAir 110AT can also be applied to poured concrete, steel, wood based, Nudura Insulated Concrete Forms (ICF), and insulated concrete forms substrate, as well as serve as detailing or a transition membrane into window and door openings.
Performance Data
Water Vapor Transmission
An imperial perm is defined as 1 grain of water vapor per hour, per square foot, per inch of mercury
perm (imperial)
0.02
Tensile Strength
Weight needed to break the roll, per inch of width
lbs / in
28
Product Weight Per Area
lb / ft ^ 2
0.17
Minimum Application Temperature
Minimum temperature that the product can be applied or installed
°F
20
Air Permeance
Rate of airflow through the barrier per square foot at a specified pressure difference
cfm /ft^2 @ 1.57 psf
0.0002
Certifications

ASTM
E-84 Certified

LEED
Certified

National Fire Protection Association (NFPA)
285 Certified

UL Solutions
GREENGUARD Gold Certification
Tremco
3735 Green Road Beachwood Cleveland 44122
800.321.7906
More to Explore
All Window Categories
Discover more than 100 curated collections of windows to inspire your next project.
Cost Estimator
Understand how the frame material, type, and glazing affect a window’s cost & see price ranges.
3-Part Specs
Download manufacturer specs from more than 7,000 residential & commercial windows.