Vapor Retarder (Class I) Vapor Retarder (Class I)

Mechanically Attached Mechanically Attached

Polymer Polymer

Ceiling, Sloped Roof, Wall Ceiling, Sloped Roof, Wall

Concrete, Masonry Concrete, Masonry

Design Options

Product Description

Viper II Platinum is an under-slab vapor retarder specifically designed for preventing moisture migration through concrete slabs-on-grade. Viper II Platinum is the first of its kind able to achieve ASTM E 1745 Class A status for blown films under 10-mils thick.

Sheet Width

Width

Standard Sizes: 14' 0"

Height

Thickness

Sheet Length

Width

Height

Standard Sizes: 17' 6"

Thickness

Thickness

Width

Height

Thickness

Standard Sizes: 0"

Manufacturer Design Notes

Viper II Platinum controls condensation, mold, mildew, degradation and prevents costly flooring failures and damage to moisture sensitive furnishings within a building’s interior. Viper II Platinum may be used to reduce radon and methane gas migration and is resistant to other adverse soil conditions.

Performance Data

Air Permeance

Rate of airflow through the barrier per square foot at a specified pressure difference

Product Weight Per Area

Water Vapor Transmission

An imperial perm is defined as 1 grain of water vapor per hour, per square foot, per inch of mercury

perm (imperial)

0.032

Roll Tensile Strength

Weight needed to break the roll, per inch of width

lbs / in

52

Minimum Temperature Rating

The lowest temperature that the product has been confirmed to still function at.

°F

-70