All of our information is sourced from manufacturer data.

Air-Shield SMP

WR Meadows

Air-Shield SMP

One-Click Request

Acelab will find & contact reps to deliver answers to your inbox.

Overview

Air Barrier Air Barrier

Fully Adhering Fully Adhering

Proprietary Material Proprietary Material

Ceiling, Sloped Roof, Wall Ceiling, Sloped Roof, Wall

Concrete, Masonry, Metal, Wood Sheathing Concrete, Masonry, Metal, Wood Sheathing

Design Options

Product Description

AIR-SHIELD SMP is a self-adhering, vapor permeable, air/liquid moisture barrier that is designed to be fully bonded to the substrate without the use of an adhesive or primer. AIR-SHIELD SMP is a tough, durable membrane that exhibits excellent resistance to air leakage and liquid water intrusion, while at the same time allows vapor to readily pass through to allow the wall assembly to dry.

Sheet Width

Width

Standard Sizes: 4' 11"

Height

Thickness

Sheet Length

Width

Height

Standard Sizes: 13' 8"

Thickness

Thickness

Width

Height

Thickness

Standard Sizes: 0"

Manufacturer Design Notes

AIR-SHIELD SMP may be applied to most common surfaces and integrated into various wall assemblies. AIR-SHIELD SMP is suitable for both new construction and retrofit applications and works equally well as an air barrier on precast concrete, cast-in-place concrete, masonry (concrete block), interior and exterior gypsum board, Styrofoam, primed steel, aluminum mill finish, anodized aluminum, primed galvanized metal, drywall, and plywood.

Performance Data

Roll Tensile Strength

Weight needed to break the roll, per inch of width

Water Vapor Transmission

An imperial perm is defined as 1 grain of water vapor per hour, per square foot, per inch of mercury

perm (imperial)

41

Product Weight Per Area

lb / ft ^ 2

53

Minimum Temperature Rating

The lowest temperature that the product has been confirmed to still function at.

°F

-40

Minimum Application Temperature

Minimum temperature that the product can be applied or installed

°F

14

Film Tensile Strength

Pressure required to break the film

psi

50

Air Permeance

Rate of airflow through the barrier per square foot at a specified pressure difference

cfm /ft^2 @ 1.57 psf

0.0008